{"id":1052,"date":"2025-03-11T15:56:15","date_gmt":"2025-03-11T14:56:15","guid":{"rendered":"https:\/\/zpum.pl\/faq\/"},"modified":"2025-03-21T14:20:34","modified_gmt":"2025-03-21T13:20:34","slug":"faq","status":"publish","type":"page","link":"https:\/\/zpum.pl\/en\/faq\/","title":{"rendered":"FAQ"},"content":{"rendered":"\t\t<div data-elementor-type=\"wp-page\" data-elementor-id=\"1052\" class=\"elementor elementor-1052 elementor-346\" data-elementor-post-type=\"page\">\n\t\t\t\t<div class=\"elementor-element elementor-element-069744c e-flex e-con-boxed e-con e-parent\" data-id=\"069744c\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-5bfa86c e-flex e-con-boxed e-con e-parent\" data-id=\"5bfa86c\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-3e1b735 elementor-widget elementor-widget-n-accordion\" data-id=\"3e1b735\" data-element_type=\"widget\" data-e-type=\"widget\" data-settings=\"{&quot;default_state&quot;:&quot;expanded&quot;,&quot;max_items_expended&quot;:&quot;one&quot;,&quot;n_accordion_animation_duration&quot;:{&quot;unit&quot;:&quot;ms&quot;,&quot;size&quot;:400,&quot;sizes&quot;:[]}}\" data-widget_type=\"nested-accordion.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<div class=\"e-n-accordion\" aria-label=\"Accordion. Open links with Enter or Space, close with Escape, and navigate with Arrow Keys\">\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-6510\" class=\"e-n-accordion-item\" open>\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"1\" tabindex=\"0\" aria-expanded=\"true\" aria-controls=\"e-n-accordion-item-6510\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> 1. Please give me your opinion on the use of your pre-insulated pipes for chilled water transfer. <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-circle-up\" viewBox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M8 256C8 119 119 8 256 8s248 111 248 248-111 248-248 248S8 393 8 256zm231-113.9L103.5 277.6c-9.4 9.4-9.4 24.6 0 33.9l17 17c9.4 9.4 24.6 9.4 33.9 0L256 226.9l101.6 101.6c9.4 9.4 24.6 9.4 33.9 0l17-17c9.4-9.4 9.4-24.6 0-33.9L273 142.1c-9.4-9.4-24.6-9.4-34 0z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-circle-down\" viewBox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M504 256c0 137-111 248-248 248S8 393 8 256 119 8 256 8s248 111 248 248zM273 369.9l135.5-135.5c9.4-9.4 9.4-24.6 0-33.9l-17-17c-9.4-9.4-24.6-9.4-33.9 0L256 285.1 154.4 183.5c-9.4-9.4-24.6-9.4-33.9 0l-17 17c-9.4 9.4-9.4 24.6 0 33.9L239 369.9c9.4 9.4 24.6 9.4 34 0z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-6510\" class=\"elementor-element elementor-element-0b6c675 e-con-full e-flex e-con e-child\" data-id=\"0b6c675\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-8152307 link elementor-widget elementor-widget-text-editor\" data-id=\"8152307\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Subject: application of pre-insulated steel double pipes for outdoor chilled water installation.<br \/>We kindly ask for your opinion whether the preinsulated steel double pipes manufactured by your company can be used<br \/>for the transmission of chilled water.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-f5ed3c7 link elementor-widget elementor-widget-text-editor\" data-id=\"f5ed3c7\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Technical and operational parameters of the transmitted medium:<br \/>&#8211; minimum temperature &#8211; 3\u00b0C<br \/>&#8211; maximum operating pressure &#8211; up to 4 bar<br \/>&#8211; type of medium &#8211; 30% water solution of propylene glycol<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-6511\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"2\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-6511\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> 2. In connection with the implementation of the construction of a low-parameter heat network of preinsulated steel pipes with the use of heat shrinkable couplings and the discovery of a high level of groundwater, we ask for an opinion on the possibility of using preinsulated steel pipes with heat shrinkable couplings below the level of occurrence of groundwater. <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-circle-up\" viewBox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M8 256C8 119 119 8 256 8s248 111 248 248-111 248-248 248S8 393 8 256zm231-113.9L103.5 277.6c-9.4 9.4-9.4 24.6 0 33.9l17 17c9.4 9.4 24.6 9.4 33.9 0L256 226.9l101.6 101.6c9.4 9.4 24.6 9.4 33.9 0l17-17c9.4-9.4 9.4-24.6 0-33.9L273 142.1c-9.4-9.4-24.6-9.4-34 0z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-circle-down\" viewBox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M504 256c0 137-111 248-248 248S8 393 8 256 119 8 256 8s248 111 248 248zM273 369.9l135.5-135.5c9.4-9.4 9.4-24.6 0-33.9l-17-17c-9.4-9.4-24.6-9.4-33.9 0L256 285.1 154.4 183.5c-9.4-9.4-24.6-9.4-33.9 0l-17 17c-9.4 9.4-9.4 24.6 0 33.9L239 369.9c9.4 9.4 24.6 9.4 34 0z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-6511\" class=\"elementor-element elementor-element-e24ad03 e-con-full e-flex e-con e-child\" data-id=\"e24ad03\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-5439406 link elementor-widget elementor-widget-text-editor\" data-id=\"5439406\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Subject: use of TS type cross-linked heat shrinkable joints in the zone below the level of occurrence of groundwater.<br \/>In response to your question, Zak\u0142ad Produkcyjno Us\u0142ugowy Mi\u0119dzyrzecz POLSKIE RURY PREIZOLOWANE<br \/>Sp. z o.o., 4 Zakaszewskiego St., Mi\u0119dzyrzecz, as a manufacturer of preinsulated products of the ZPU Mi\u0119dzyrzecz Sp. z o.o. system, confirms the possibility of using TS-type heat shrinkable joints on district heating networks laid in the ground below the level of ground water occurrence. However, in order to achieve greater tightness of the joint and as a protection against workmanship errors, we recommend additionally using heat shrinkable bands as a second seal.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-8f8a804 link elementor-widget elementor-widget-text-editor\" data-id=\"8f8a804\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>In addition, we would like to inform you that the TS connectors offered by us with double sealing (with the use of a cap<br \/>and additional shrinking bands with glue), are manufactured in compliance with PN-EN 489 standard and ensure 100% watertightness, provided that they are properly assembled in accordance with the \u201cManual for making and sealing a TS-type connector assembly \u201dof the ZPU Mi\u0119dzyrzecz Sp. z o.o. system, by personnel having the appropriate skills and experience, and above all a certificate of completion of training, issued by Zak\u0142ad Produkcyjno Us\u0142ugowy Mi\u0119dzyrzecz POLSKIE RURY PREIZOLOWANE Sp. z o.o. with its registered office at 4 Zakaszewskiego St. in Mi\u0119dzyrzecz (Poland).<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-6512\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"3\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-6512\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> 3. How and if at all it is possible to combine M-Pex\u00ae pipes with traditional pre-insulated steel pipes. I am in the process of preparing a request for proposal for the supply of pipes and I am analyzing various options for implementation. In the description of M-Pex\u00ae pipes, it says that they are intended for the distribution of water from the source of generation to the consumer. In our case, it is the connection to the existing network made traditionally. <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-circle-up\" viewBox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M8 256C8 119 119 8 256 8s248 111 248 248-111 248-248 248S8 393 8 256zm231-113.9L103.5 277.6c-9.4 9.4-9.4 24.6 0 33.9l17 17c9.4 9.4 24.6 9.4 33.9 0L256 226.9l101.6 101.6c9.4 9.4 24.6 9.4 33.9 0l17-17c9.4-9.4 9.4-24.6 0-33.9L273 142.1c-9.4-9.4-24.6-9.4-34 0z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-circle-down\" viewBox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M504 256c0 137-111 248-248 248S8 393 8 256 119 8 256 8s248 111 248 248zM273 369.9l135.5-135.5c9.4-9.4 9.4-24.6 0-33.9l-17-17c-9.4-9.4-24.6-9.4-33.9 0L256 285.1 154.4 183.5c-9.4-9.4-24.6-9.4-33.9 0l-17 17c-9.4 9.4-9.4 24.6 0 33.9L239 369.9c9.4 9.4 24.6 9.4 34 0z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-6512\" class=\"elementor-element elementor-element-72bc5ab e-con-full e-flex e-con e-child\" data-id=\"72bc5ab\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-ecd8847 link elementor-widget elementor-widget-text-editor\" data-id=\"ecd8847\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Responding to the question on combining M-Pex\u00ae pipes with steel pre-insulated pipes, we would like to inform you as follows:<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-da3bd22 elementor-widget elementor-widget-image\" data-id=\"da3bd22\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img fetchpriority=\"high\" decoding=\"async\" width=\"554\" height=\"207\" src=\"https:\/\/zpum.pl\/wp-content\/uploads\/faq1.jpg\" class=\"attachment-large size-large wp-image-348\" alt=\"\" srcset=\"https:\/\/zpum.pl\/wp-content\/uploads\/faq1.jpg 554w, https:\/\/zpum.pl\/wp-content\/uploads\/faq1-300x112.jpg 300w, https:\/\/zpum.pl\/wp-content\/uploads\/faq1-150x56.jpg 150w\" sizes=\"(max-width: 554px) 100vw, 554px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-eaf0540 link elementor-widget elementor-widget-text-editor\" data-id=\"eaf0540\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Photo No. 1 and 2 Transition fitting HELA H, PN 6 and PN 10 for \u00f825\u00f7\u00f832 mm<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-cb12421 elementor-widget elementor-widget-image\" data-id=\"cb12421\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img decoding=\"async\" width=\"554\" height=\"207\" src=\"https:\/\/zpum.pl\/wp-content\/uploads\/faq2.jpg\" class=\"attachment-large size-large wp-image-349\" alt=\"\" srcset=\"https:\/\/zpum.pl\/wp-content\/uploads\/faq2.jpg 554w, https:\/\/zpum.pl\/wp-content\/uploads\/faq2-300x112.jpg 300w, https:\/\/zpum.pl\/wp-content\/uploads\/faq2-150x56.jpg 150w\" sizes=\"(max-width: 554px) 100vw, 554px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-dacd602 link elementor-widget elementor-widget-text-editor\" data-id=\"dacd602\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Photo No. 3 and 4 HELA H, PN 6 and PN10 transition coupling for \u00f840\u00f7\u00f8110 mm<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-910889f elementor-widget elementor-widget-image\" data-id=\"910889f\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img decoding=\"async\" width=\"554\" height=\"207\" src=\"https:\/\/zpum.pl\/wp-content\/uploads\/faq3.jpg\" class=\"attachment-large size-large wp-image-350\" alt=\"\" srcset=\"https:\/\/zpum.pl\/wp-content\/uploads\/faq3.jpg 554w, https:\/\/zpum.pl\/wp-content\/uploads\/faq3-300x112.jpg 300w, https:\/\/zpum.pl\/wp-content\/uploads\/faq3-150x56.jpg 150w\" sizes=\"(max-width: 554px) 100vw, 554px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-b7d3757 link elementor-widget elementor-widget-text-editor\" data-id=\"b7d3757\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Photo Nos. 5 and 6 Straight fitting with female thread HELA M<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-bb9d013 link elementor-widget elementor-widget-text-editor\" data-id=\"bb9d013\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>3.1 It is possible to connect M-Pex\u00ae pipes with pre-insulated steel pipes.<br \/>3.2 These connections are made in two ways:<br \/>&#8211; carrier pipes are mechanically connected with couplings of type ,,H\u201c (Photo Nos. 1\u00f74) and ,,M\u201d (Photo Nos. 5 and 6),<\/p><p>&#8211; it is possible to weld pipes with the use of coupling type ,,P\u201d (Photo No. 7 and 8) with a welding end \/applies only to M-Pex\u00ae 6 bar pipes\/.<\/p><p>3.3 Pipeline connections are insulated at the construction site using NT-type or TS-type heat shrinkable couplings<br \/>with the appropriate size for the pipes to be joined.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-6513\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"4\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-6513\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> 4. Please confirm the possibility of using M-Pex\u00ae pre-insulated pipes without protective pipes and strain relief plates for pipes buried at a depth of 1.2m under the parking slab for cars and trucks and partially under the roadway. <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-circle-up\" viewBox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M8 256C8 119 119 8 256 8s248 111 248 248-111 248-248 248S8 393 8 256zm231-113.9L103.5 277.6c-9.4 9.4-9.4 24.6 0 33.9l17 17c9.4 9.4 24.6 9.4 33.9 0L256 226.9l101.6 101.6c9.4 9.4 24.6 9.4 33.9 0l17-17c9.4-9.4 9.4-24.6 0-33.9L273 142.1c-9.4-9.4-24.6-9.4-34 0z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-circle-down\" viewBox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M504 256c0 137-111 248-248 248S8 393 8 256 119 8 256 8s248 111 248 248zM273 369.9l135.5-135.5c9.4-9.4 9.4-24.6 0-33.9l-17-17c-9.4-9.4-24.6-9.4-33.9 0L256 285.1 154.4 183.5c-9.4-9.4-24.6-9.4-33.9 0l-17 17c-9.4 9.4-9.4 24.6 0 33.9L239 369.9c9.4 9.4 24.6 9.4 34 0z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-6513\" class=\"elementor-element elementor-element-5f51be6 e-con-full e-flex e-con e-child\" data-id=\"5f51be6\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-5770db7 link elementor-widget elementor-widget-text-editor\" data-id=\"5770db7\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Zak\u0142ad Produkcyjno Us\u0142ugowy Mi\u0119dzyrzecz POLSKIE RURY PREIZOLOWANE Sp. z o.o., 4 Zakaszewskiego St., as the manufacturer of M-Pex\u00ae preinsulated pipes of the ZPU Mi\u0119dzyrzecz Sp. z o.o. system, confirms the possibility of using the above-mentioned pipes laid in the ground at a depth of 1.2m under the parking slab, intended for cars and trucks, and partially under the roadway, without the need for protective pipes and pressure relieving plates.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-6514\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"5\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-6514\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> 5. Please provide the conditions for the installation of pre-insulated compensator type KP-168-125. <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-circle-up\" viewBox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M8 256C8 119 119 8 256 8s248 111 248 248-111 248-248 248S8 393 8 256zm231-113.9L103.5 277.6c-9.4 9.4-9.4 24.6 0 33.9l17 17c9.4 9.4 24.6 9.4 33.9 0L256 226.9l101.6 101.6c9.4 9.4 24.6 9.4 33.9 0l17-17c9.4-9.4 9.4-24.6 0-33.9L273 142.1c-9.4-9.4-24.6-9.4-34 0z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-circle-down\" viewBox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M504 256c0 137-111 248-248 248S8 393 8 256 119 8 256 8s248 111 248 248zM273 369.9l135.5-135.5c9.4-9.4 9.4-24.6 0-33.9l-17-17c-9.4-9.4-24.6-9.4-33.9 0L256 285.1 154.4 183.5c-9.4-9.4-24.6-9.4-33.9 0l-17 17c-9.4 9.4-9.4 24.6 0 33.9L239 369.9c9.4 9.4 24.6 9.4 34 0z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-6514\" class=\"elementor-element elementor-element-47b6c35 e-con-full e-flex e-con e-child\" data-id=\"47b6c35\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-1cefbb2 link elementor-widget elementor-widget-text-editor\" data-id=\"1cefbb2\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Zak\u0142ad Produkcyjno Us\u0142ugowy POLSKIE RURY PREIZOLOWANE Sp. z o.o. ul. Zakaszewskiego 4, informs that during the installation of the bellows compensator type KP-168-125, it is necessary to maintain alignment in the vertical and horizontal planes, deviation of the compensator&#8217;s axis from the axis of the pipeline may not be greater than 0.5\u00b0 over a section of min. 12m on both sides of the compensator. Also, fittings (tees, shut-off valves) that could cause lateral forces cannot be installed on these sections. In the 12m section before and after the compensator, the backfill must be compacted to ID=1 according to PN-B-06050, which will act as a directional support. The distance between the compensators must result from the calculations, which must take into account the embedment, the length of the pipeline the temperature of the heating medium and the friction forces occurring on the side of the casing pipe. The calculated elongation of the pre-insulated pipeline must not exceed its compensation capacity.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-6515\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"6\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-6515\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> 6. Please tell me, when installing pre-insulated pipes with impulse leak detection alarm system, is the direction of pipe alignment important or does it not matter? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-circle-up\" viewBox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M8 256C8 119 119 8 256 8s248 111 248 248-111 248-248 248S8 393 8 256zm231-113.9L103.5 277.6c-9.4 9.4-9.4 24.6 0 33.9l17 17c9.4 9.4 24.6 9.4 33.9 0L256 226.9l101.6 101.6c9.4 9.4 24.6 9.4 33.9 0l17-17c9.4-9.4 9.4-24.6 0-33.9L273 142.1c-9.4-9.4-24.6-9.4-34 0z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-circle-down\" viewBox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M504 256c0 137-111 248-248 248S8 393 8 256 119 8 256 8s248 111 248 248zM273 369.9l135.5-135.5c9.4-9.4 9.4-24.6 0-33.9l-17-17c-9.4-9.4-24.6-9.4-33.9 0L256 285.1 154.4 183.5c-9.4-9.4-24.6-9.4-33.9 0l-17 17c-9.4 9.4-9.4 24.6 0 33.9L239 369.9c9.4 9.4 24.6 9.4 34 0z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-6515\" class=\"elementor-element elementor-element-3dfbca9 e-con-full e-flex e-con e-child\" data-id=\"3dfbca9\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-7d5026a link elementor-widget elementor-widget-text-editor\" data-id=\"7d5026a\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>We would like to inform you that pre-insulated elements that are equipped with impulse alarm installation should be laid in the trench so that the manufacturer&#8217;s label is always on one side of the connector &#8211; lay with the label towards the power source. This is to ensure the correct connection of the alarm installation wires. The alarm installation wires should be at the top of the pre-insulated pipe, in the \u201c10 a.m.\u201d and \u201c2 p.m.\u201d alignment. (the tin whitened wire should be on the right side looking in accordance with the direction of the flow of the medium from the heat source, and the copper wire on the left side). Then the unipolar wires are opposite each other.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-6516\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"7\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-6516\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> 7. Can pre-insulated products with steel carrier pipe be gas welded? Is this posted somewhere as written in your guidelines for the installation of pre-insulated pipe heat networks? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-circle-up\" viewBox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M8 256C8 119 119 8 256 8s248 111 248 248-111 248-248 248S8 393 8 256zm231-113.9L103.5 277.6c-9.4 9.4-9.4 24.6 0 33.9l17 17c9.4 9.4 24.6 9.4 33.9 0L256 226.9l101.6 101.6c9.4 9.4 24.6 9.4 33.9 0l17-17c9.4-9.4 9.4-24.6 0-33.9L273 142.1c-9.4-9.4-24.6-9.4-34 0z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-circle-down\" viewBox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M504 256c0 137-111 248-248 248S8 393 8 256 119 8 256 8s248 111 248 248zM273 369.9l135.5-135.5c9.4-9.4 9.4-24.6 0-33.9l-17-17c-9.4-9.4-24.6-9.4-33.9 0L256 285.1 154.4 183.5c-9.4-9.4-24.6-9.4-33.9 0l-17 17c-9.4 9.4-9.4 24.6 0 33.9L239 369.9c9.4 9.4 24.6 9.4 34 0z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-6516\" class=\"elementor-element elementor-element-b66102d e-con-full e-flex e-con e-child\" data-id=\"b66102d\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-2d9d800 link elementor-widget elementor-widget-text-editor\" data-id=\"2d9d800\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>According to the information contained in our \u201cManual of execution and acceptance\u201d of the system of ZPU Miedzyrzecz Sp. z o.o. (page 7) all connections of steel line pipes are to be made by arc welding. Gas welding is allowed only for steel line pipes with a wall thickness of up to 2.9mm. In addition, according to the \u201cInstruction for Welding of Conduit Pipes of District Heating Networks from Preinsulated Pipes and Elements\u201d contained in the \u201cTechnical Conditions for Execution and Acceptance of District Heating Networks from Preinsulated Pipes and Elements\u201d-Essue 4, issued by COBRTI INSTAL for larger wall thicknesses for gas welding, the approval of the owner of the network must be obtained.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-6517\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"8\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-6517\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> 8 On a straight section of DN80\/160 pre-insulated pipeline with a length of about 100 m, measured from the 90\u00b0 elbow to the 90\u00b0 elbow, can a parallel tee with a branch diameter of DN50\/125 located at a distance of about 12 mb from the compensation elbow be designed? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-circle-up\" viewBox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M8 256C8 119 119 8 256 8s248 111 248 248-111 248-248 248S8 393 8 256zm231-113.9L103.5 277.6c-9.4 9.4-9.4 24.6 0 33.9l17 17c9.4 9.4 24.6 9.4 33.9 0L256 226.9l101.6 101.6c9.4 9.4 24.6 9.4 33.9 0l17-17c9.4-9.4 9.4-24.6 0-33.9L273 142.1c-9.4-9.4-24.6-9.4-34 0z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-circle-down\" viewBox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M504 256c0 137-111 248-248 248S8 393 8 256 119 8 256 8s248 111 248 248zM273 369.9l135.5-135.5c9.4-9.4 9.4-24.6 0-33.9l-17-17c-9.4-9.4-24.6-9.4-33.9 0L256 285.1 154.4 183.5c-9.4-9.4-24.6-9.4-33.9 0l-17 17c-9.4 9.4-9.4 24.6 0 33.9L239 369.9c9.4 9.4 24.6 9.4 34 0z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-6517\" class=\"elementor-element elementor-element-87a8a3f e-con-full e-flex e-con e-child\" data-id=\"87a8a3f\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-152dfe5 link elementor-widget elementor-widget-text-editor\" data-id=\"152dfe5\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>According to the \u201cDesign Guidelines\u201d of the system of ZPU Miedzyrzecz sp. z o.o., parallel tees should be designed at a distance of no more than 2\/3 of the length Lmax from the actual fixed or virtual point (as shown in the figure below). In this case, Lmax for DN80\/160 is 55m, for an average pipeline laying at a depth of 1.0m measured from the ground surface to the axis of the pipeline, hence the TR-80\/50 tee should be located no more than 2\/3\u00d755m = 36.6m from the virtual fixed point. The distance of the tee branch from the 90\u00b0 elbow is:<br \/>(100m:2) -36.6m = 13.4m. The length of the compensation arm of the parallel branch [L&#8217;] is calculated, as for compensation in the \u201cL\u201d-shaped system, according to the \u201cGuidelines for the Design of the System of ZPU Miedzyrzecz Ltd.\u201d<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-fc2ee4c elementor-widget elementor-widget-image\" data-id=\"fc2ee4c\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"420\" height=\"264\" src=\"https:\/\/zpum.pl\/wp-content\/uploads\/faq4.jpg\" class=\"attachment-large size-large wp-image-351\" alt=\"\" srcset=\"https:\/\/zpum.pl\/wp-content\/uploads\/faq4.jpg 420w, https:\/\/zpum.pl\/wp-content\/uploads\/faq4-300x189.jpg 300w, https:\/\/zpum.pl\/wp-content\/uploads\/faq4-150x94.jpg 150w\" sizes=\"(max-width: 420px) 100vw, 420px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-3683657 link elementor-widget elementor-widget-text-editor\" data-id=\"3683657\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>In addition, we would like to inform you that you should not design the preinsulated parallel branch of the thermal network as an extension of the main section using a parallel tee, and you should not install preinsulated shut-off, venting, drainage fittings and preinsulated branches in the calculated compensation zones.<br \/>The figure below shows an incorrectly designed section of the thermal network.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-55f1d0d elementor-widget elementor-widget-image\" data-id=\"55f1d0d\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"420\" height=\"127\" src=\"https:\/\/zpum.pl\/wp-content\/uploads\/faq5.jpg\" class=\"attachment-large size-large wp-image-352\" alt=\"\" srcset=\"https:\/\/zpum.pl\/wp-content\/uploads\/faq5.jpg 420w, https:\/\/zpum.pl\/wp-content\/uploads\/faq5-300x91.jpg 300w, https:\/\/zpum.pl\/wp-content\/uploads\/faq5-150x45.jpg 150w\" sizes=\"(max-width: 420px) 100vw, 420px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t\t<details id=\"e-n-accordion-item-6518\" class=\"e-n-accordion-item\" >\n\t\t\t\t<summary class=\"e-n-accordion-item-title\" data-accordion-index=\"9\" tabindex=\"-1\" aria-expanded=\"false\" aria-controls=\"e-n-accordion-item-6518\" >\n\t\t\t\t\t<span class='e-n-accordion-item-title-header'><div class=\"e-n-accordion-item-title-text\"> 9. We ask for an answer, what to do in the situation when, after the welding work on the heat pipeline and leakage tests, rainfall caused flooding and silting by sand of the mounting holes? How can the shrinking of the heat shrink coupler be \u201cstrengthened\u201d? <\/div><\/span>\n\t\t\t\t\t\t\t<span class='e-n-accordion-item-title-icon'>\n\t\t\t<span class='e-opened' ><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-circle-up\" viewBox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M8 256C8 119 119 8 256 8s248 111 248 248-111 248-248 248S8 393 8 256zm231-113.9L103.5 277.6c-9.4 9.4-9.4 24.6 0 33.9l17 17c9.4 9.4 24.6 9.4 33.9 0L256 226.9l101.6 101.6c9.4 9.4 24.6 9.4 33.9 0l17-17c9.4-9.4 9.4-24.6 0-33.9L273 142.1c-9.4-9.4-24.6-9.4-34 0z\"><\/path><\/svg><\/span>\n\t\t\t<span class='e-closed'><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-circle-down\" viewBox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M504 256c0 137-111 248-248 248S8 393 8 256 119 8 256 8s248 111 248 248zM273 369.9l135.5-135.5c9.4-9.4 9.4-24.6 0-33.9l-17-17c-9.4-9.4-24.6-9.4-33.9 0L256 285.1 154.4 183.5c-9.4-9.4-24.6-9.4-33.9 0l-17 17c-9.4 9.4-9.4 24.6 0 33.9L239 369.9c9.4 9.4 24.6 9.4 34 0z\"><\/path><\/svg><\/span>\n\t\t<\/span>\n\n\t\t\t\t\t\t<\/summary>\n\t\t\t\t<div role=\"region\" aria-labelledby=\"e-n-accordion-item-6518\" class=\"elementor-element elementor-element-f8b200b e-con-full e-flex e-con e-child\" data-id=\"f8b200b\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-dcbf3b2 link elementor-widget elementor-widget-text-editor\" data-id=\"dcbf3b2\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>In response to your question, Zak\u0142ad Produkcyjno Us\u0142ugowy Mi\u0119dzyrzecz POLSKIE RURY PREIZOLOWANE<br \/>Sp. z o.o., 4 Zakaszewskiego St., I would like to inform you that the installation of NT-type heat shrinkable joints should be carried out in accordance with the \u201cInstructions for the Construction and Encapsulation of the Joint Assembly\u201d of the ZPU Mi\u0119dzyrzecz Sp. z o.o. system in favourable weather conditions. If during the installation of the preinsulated network, after the welding work and leakage tests, due to heavy rainfall the installation trenches, where the preinsulated pipelines were fitted with heat shrinkable sleeves and heat shrinkable bands, were flooded and silted by sand, we propose to additionally use 10 cm wide bituminous tape for joint encapsulation, according to the instruction prepared for you and attached to this letter.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-d486c45 link elementor-widget elementor-widget-text-editor\" data-id=\"d486c45\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Particular attention should be paid to thoroughly clean the outer and inner surfaces of the shrink sleeve immediately before installing it<br \/>and inner surface. For this purpose, it is necessary to:<br \/>&#8211; thoroughly remove sand from the inner part of the cap,<br \/>&#8211; remove the film protecting the adhesive, located inside the cap,<br \/>&#8211; carefully clean the inner and outer surface from dirt and dust with acetone, and then dry.<br \/>After cleaning the cap, especially on its inner surface, there should not be any contaminants that can weaken the adhesion of the cap in the shrinking zone. The strength and tightness of the shrink joint depends on the accuracy of cleaning the cap.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-9428831 link elementor-widget elementor-widget-text-editor\" data-id=\"9428831\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>All other activities related to the installation of NT-type connectors should be carried out strictly according to the following instructions.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-95a8df6 link elementor-widget elementor-widget-text-editor\" data-id=\"95a8df6\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p><strong>INSTALLATION MANUAL<\/strong><\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-9a89751 link elementor-widget elementor-widget-text-editor\" data-id=\"9a89751\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>additional sealing &#8211; bituminous tape 10 cm wide &#8211; for heat shrinkable joints type NT System ZPU Mi\u0119dzyrzecz Sp. z o.o.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-94702f1 link elementor-widget elementor-widget-text-editor\" data-id=\"94702f1\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<div><p data-pm-slice=\"1 1 []\">I. Introduction<\/p><p>This instruction manual describes the procedure for applying additional sealing to NT-type heat-shrinkable joints of the ZPU Mi\u0119dzyrzecz Sp. z o.o. System by using a 10 cm wide bitumen tape between the HDPE protective pipe of the connected pre-insulated products and the heat-shrinkable sleeve.<\/p><p>This instruction should only be applied when, during the installation of the heating network, adverse weather conditions or unintended actions at the construction site have resulted in contamination or damage to the bitumen adhesive layer lining the inner surfaces of the heat-shrinkable sleeve ends.<\/p><p>II. General Conditions for Thermal Insulation and Hermetization of NT Joints<\/p><ol start=\"1\" data-spread=\"false\"><li><p>Thermal insulation and hermetization can only be performed after:<\/p><ul data-spread=\"false\"><li><p>A successfully conducted pressure leak test of the pipeline,<\/p><\/li><li><p>Inspection and acceptance of welded joints in accordance with PN-EN 970:1999 (&#8220;Visual examination of welded joints&#8221;), PN-EN 1435:2001 (&#8220;Radiographic examination of welded joints&#8221;), PN-EN 1714 (&#8220;Non-destructive testing of welded joints. Ultrasonic testing&#8221;), PN-EN 25817:1997 (&#8220;Arc-welded steel joints. Guidelines for defining quality levels based on welding defects&#8221;), and PN-EN 26520:1997 (&#8220;Classification of welding defects in welded joints with explanations&#8221;),<\/p><\/li><li><p>In the case of an installed pipeline leak detection system, after connecting the signal wires and conducting technical tests in accordance with the instructions &#8220;Leak Detection of Pipelines \u2013 Signal Wire Connections,&#8221; &#8220;Pipeline Leak Detection \u2013 Signal Wire Connections,&#8221; or &#8220;Installation Manual for the BRANDES System for Pipework with a Plastic Sheath.&#8221;<\/p><\/li><\/ul><\/li><\/ol><p>The heat-shrinkable sleeve must be stored in white foil at a temperature below 25\u00b0C in a shaded area until immediately before shrinkage. Failure to meet these conditions may result in sleeve deformation.<\/p><ol start=\"2\" data-spread=\"true\"><li><p>Thermal insulation and hermetization should preferably be performed under favorable weather conditions\u2014in dry, sunny weather with an ambient temperature above +5\u00b0C. If hermetization must be performed in high humidity (rainfall), these operations should be carried out under a portable shelter, such as a tarpaulin tent.<\/p><\/li><li><p>Thermal insulation and hermetization should be carried out by a trained worker with a certificate authorizing the performance of the aforementioned activities, issued by ZPU Mi\u0119dzyrzecz Sp. z o.o.<\/p><\/li><li><p>The surface temperature of the carrier and protective pipe during thermal insulation should be 30\u00b0C to 35\u00b0C.<\/p><\/li><li><p>The polyurethane foam at the ends of the pre-insulated pipes must be dry. A portion of the foam at the joint faces of the pre-insulated elements should be removed to a depth of up to 15 mm.<\/p><\/li><li><p>The carrier pipe in the joint assembly must be cleaned of contaminants, dust, etc.<\/p><\/li><li><p>The surface of the protective pipe should be cleaned and dried up to 30 cm from the pipe end.<\/p><\/li><li><p>The excavation at the location of thermal insulation and hermetization of the joint assembly should be widened and deepened by approximately 20 cm.<\/p><\/li><li><p>The joint cover\u2014either an HDPE polyethylene sleeve or a heat-shrinkable HDPE polyethylene sleeve, as well as heat-shrinkable bands\u2014should be placed on the pre-insulated pipe before welding the steel carrier pipe.<\/p><\/li><\/ol><p>III. Preparatory and Auxiliary Activities<\/p><ol start=\"1\" data-spread=\"true\"><li><p>Begin thermal insulation by removing, using a knife or scraper, part of the PUR foam insulation from the joint faces of the connected pre-insulated elements to a depth of up to 15 mm. Special attention should be paid to the condition of the polyurethane foam at the welded joint faces. If it is moist, it should be removed.<\/p><\/li><li><p>Clean the carrier pipe of contaminants, dust, etc. If the weld joint was covered with a lubricant during inspection, degrease the area using, for example, carbon tetrachloride.<\/p><\/li><li><p>Clean and dry the surface of the protective pipes of the connected pre-insulated elements over a length of about 30 cm from the edge of the protective pipe and over a length of about 1 m on one of the pre-insulated elements onto which the heat-shrinkable sleeve will be slid. To do this, remove a polyethylene layer of 0.1 to 0.25 mm thickness from the protective pipe surface. Abrasive work should be performed manually or using an electric belt sander with sandpaper of 50 to 70 grit or by hand. The prepared protective pipe surface should be cleaned of contaminants with acetone and dried using a cleaning cloth.<\/p><\/li><li><p>Carefully clean the inner and outer surfaces of the heat-shrinkable sleeve of contaminants, dust, and sand, then dry it. This includes:<\/p><ul data-spread=\"false\"><li><p>Removing sand from the inside of the sleeve,<\/p><\/li><li><p>Removing the protective foil covering the adhesive inside the sleeve,<\/p><\/li><li><p>Thoroughly cleaning the inner and outer surfaces of contaminants and dust using acetone and drying them.<\/p><\/li><\/ul><\/li><li><p>Heat the surface of the protective pipe at the joint with the sleeve and band using a propane-butane gas burner. One minute after heating is stopped, the surface temperature of the protective pipe should be at least 60\u00b0C.<\/p><\/li><\/ol><p>IV. Sequence of Activities \u2013 Thermal Insulation Execution<\/p><ol start=\"1\" data-spread=\"true\"><li><p>Slide the cleaned heat-shrinkable sleeve symmetrically onto the welded joint so that the overlap on both ends of the protective pipe is equal. Using a marker or white correction pen, mark the outer edges of the sleeve: sleeve length\u2014600 mm, total uninsulated steel pipe ends length\u2014300 mm for diameters up to DN 200 mm, so the overlap of the heat-shrinkable sleeve on the protective pipe of the welded pre-insulated elements should be: (600 &#8211; 300)\/2 = 150 mm. This 150 mm measurement should be taken from the edge of the protective pipes and marked with a white marker (correction pen) around the circumference of the protective pipe along the sleeve edge.<\/p><\/li><li><p>Measure approximately 20 mm from the marked outlines of the sleeve edges for positioning the outer edge of the bitumen tape.<\/p><\/li><li><p>Prepare two sections of bitumen tape for installation on both ends of the protective pipe of the connected pre-insulated elements. Measure and cut the tape length to allow an overlap of approximately 40 mm after wrapping it around the HDPE protective pipe.<\/p><\/li><li><p>Install the bitumen tape at both ends of the connected pre-insulated elements by wrapping it tightly around the protective pipe.<\/p><\/li><li><p>Remove the protective foil from the bitumen tape.<\/p><\/li><li><p>After placing the bitumen tape, visually inspect its correct positioning before sliding the sleeve into its final position.<\/p><\/li><li><p>Slide the heat-shrinkable sleeve into its final position.<\/p><\/li><li><p>Shrink the ends of the heat-shrinkable sleeve according to the &#8220;Joint Assembly and Hermetization Instructions&#8221; of the ZPU Mi\u0119dzyrzecz Sp. z o.o. System.<\/p><\/li><li><p>Shrink the heat-shrinkable bands on both ends of the sleeve according to the same instructions.<\/p><\/li><li><p>Perform a leak-tightness check according to the &#8220;Joint Assembly and Hermetization Instructions&#8221; and complete the thermal insulation.<\/p><\/li><\/ol><p>For any questions related to NT-type heat-shrinkable joint installation using additional bitumen tape, contact:<\/p><\/div><p><strong>Zak\u0142ad Produkcyjno Us\u0142ugowy Mi\u0119dzyrzecz POLSKIE RURY PREIZOLOWANE Sp. z o.o.,<\/strong><br \/><strong>ul. Zakaszewskiego 4,<\/strong><br \/><strong>66-300 Mi\u0119dzyrzecz<\/strong><br \/><strong>tel. +48 95 741 25 26, 741 27 01, 741 27 02, 742 00 9;<\/strong><br \/><strong>fax +48 95 742 18 36, 742 01 36<\/strong><br \/><a href=\"http:\/\/www.zpum.pl\/\" target=\"_blank\" rel=\"noopener\">www.zpum.pl<\/a><br \/><span id=\"cloak3740\"><a href=\"mailto:zpu@zpum.pl\">zpu@zpum.pl<\/a><\/span><\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/details>\n\t\t\t\t\t<\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t","protected":false},"excerpt":{"rendered":"<p>1. Please give me your opinion on the use of your pre-insulated pipes for chilled water transfer. Subject: application of pre-insulated steel double pipes for outdoor chilled water installation.We kindly ask for your opinion whether the preinsulated steel double pipes manufactured by your company can be usedfor the transmission of chilled water. Technical and operational [&hellip;]<\/p>\n","protected":false},"author":8,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"footnotes":""},"class_list":["post-1052","page","type-page","status-publish","hentry"],"_links":{"self":[{"href":"https:\/\/zpum.pl\/en\/wp-json\/wp\/v2\/pages\/1052","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/zpum.pl\/en\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/zpum.pl\/en\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/zpum.pl\/en\/wp-json\/wp\/v2\/users\/8"}],"replies":[{"embeddable":true,"href":"https:\/\/zpum.pl\/en\/wp-json\/wp\/v2\/comments?post=1052"}],"version-history":[{"count":4,"href":"https:\/\/zpum.pl\/en\/wp-json\/wp\/v2\/pages\/1052\/revisions"}],"predecessor-version":[{"id":1158,"href":"https:\/\/zpum.pl\/en\/wp-json\/wp\/v2\/pages\/1052\/revisions\/1158"}],"wp:attachment":[{"href":"https:\/\/zpum.pl\/en\/wp-json\/wp\/v2\/media?parent=1052"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}